ATLD Insertion Electromagnetic Flow Meter

Insertion Type magnetic flow meter is connected with the pipeline through the installation base, ball valve, compression nut and positioning screw. Sensor measurement is divided into two structural types: measuring tube type and plane electrode type. The measuring tube sensor is suitable for measuring the cleaning medium; Planar electrode type is suitable for liquid flow measurement with other impurities in the measuring medium.

Plug-in electromagnetic flow meter can be installed and disassembled conveniently without stopping water under low pressure or pressure. Therefore, it is very suitable for the fluid measurement of existing pipelines and convenient for the maintenance and repair of instruments.

Enquiry

Electromagnetic flow meter is a speed instrument for measuring the volume flow of conductive medium. It outputs standard current signals for recording, adjustment and control while monitoring and displaying on the spot, so as to realize automatic control of detection and remote transmission of signals.

The electromagnetic flow meter comprises of interconnected transmitters and sensors that collaborate to accurately measure fluid flow. The sensor, designed with a direct connection, quantifies the induced voltage generated by the fluid as it traverses through the pipe. Subsequently, the transmitter gauges this voltage and converts it into a precise flow rate before transmitting the measurement data to the control system.

The flow principle behind electromagnetic flow meters is called Faraday’s Law, and its mathematical expression is defined as E=k*B*D*V. The induced voltage (E) is proportional to the speed (V) of the fluid passing through the magnetic field (B). The induced voltage enters the transmitter through the electrode loop. A transmitter then converts this voltage into a quantifiable flow speed. The volumetric flow rate of the fluid is calculated using this known velocity combined with the area of the pipe.

Electromagnetic flow meters are highly suitable for a diverse range of applications across various industries, including pulp and paper, metallurgy and mining, water and wastewater treatment, food and beverages, chemicals and petrochemicals, as well as oil and gas. Due to their streamlined design without any protrusions or obstructions in the pipeline, electromagnetic flow meters can be seamlessly adapted for an extensive array of applications encompassing clean liquids, slurring, as well as highly corrosive or abrasive fluids.

Features

  • Suitable for measuring pipe diameter: DN100~3000mm
  • The measurement accuracy is not affected by the changes of physical parameters such as temperature, pressure, density, viscosity and conductivity (as long as the conductivity is greater than 20µs/cm) of the measured medium
  • The sensor has almost no pressure loss and extremely low energy loss
  • Compared with the general flowmeter, the manufacturing cost and installation cost are lower. It is especially suitable for flow measurement of large and medium diameter pipelines
  • Adopt advanced low-frequency square wave excitation. Zero point stability, strong anti-interference ability and reliable work
  • Large flow measurement range. The full-scale flow velocity in the measured pipeline can be set arbitrarily from 1m/s to 10m/s, and the output signal has a linear relationship with the flow rate
  • The flowmeter not only has (0~10)mA DC or (4~20)mA DC standard current output, but also has (1~5)kHz frequency output

Specification

SizeDN3-DN3000mm
Nominal Pressure0.6-1.6MPa (2.5MPa/4.0MPa/6.4MPa…Max 42MPa – optional)
Accuracy+/-0.5%(Standard)
or +/-0.2%(Optional)
LinerPTFE, Neoprene, Hard Rubber, EPDM, FEP, Polyurethane, PFA
ElectrodeSUS316L, Hastelloy B, Hastelloy C
Titanium, Tantalum, Platinium-iridium
Structure TypeIntegral type, remote type, submersible type, Insertion type
Medium Temperature-20~+60 degC(Integral type)
Remote type(Neoprene,Hard Rubber,Polyurethane,EPDM) -10~+80degC
Remote type(PTFE/PFA/FEP) -10~+160degC
Ambient Temperature-20~+60deg C
Ambient Humidity5-100%RH(relative humidity)
Measuring RangeMax 15m/s
Conductivity>5us/cm
Protection ClassIP65(Standard); IP68(Optional for remote type)
Process ConnectionFlange (Standard), Wafer, Thread, Tri-clamp etc (Optional)
Output Signal4-20mA/Pulse
CommunicationRS485(Standard), HART(Optional),GPRS/GSM (Optional)
Power SupplyAC220V (can be used for AC85-250V)
DC24V (can be used for DC20-36V)
DC12V (optional), Battery Powered 3.6V (optional)
Power Consumption<20W
AlarmUpper Limit Alarm / Lower Limit Alarm
Self-diagnosisEmpty Pipe Alarm, Exciting Alarm
Explosion ProofATEX

 

Comparison Table of Flow and Velocity of Electromagnetic Flowmeter

flow rate

Flow m/s

m³/h

Diameter mm

0.10.51234510
DN100.02830.14140.28270.56540.84821.13091.41372.8270
DN150.06360.31810.63621.27231.90852.54473.18096.3620
DN200.11310.56551.13102.26193.39294.52395.654911.310
DN250.17670.88361.76713.53435.30147.06868.835717.671
DN320.28951.44762.89535.79068.685911.58114.47728.953
DN400.45242.26194.52399.047813.57218.09622.62045.239
DN500.70683.53437.068614.13721.20628.27435.34370.686
DN651.19465.973011.94623.89235.83847.78459.730119.460
DN801.80969.047818.09636.19154.28772.38290.478180.956
DN1002.827414.13728.27456.54984.823113.097141.372282.743
DN1254.417922.08944.17988.357132.536176.715220.893441.786
DN1506.361831.80963.618127.235190.852254.469318.086636.173
DN20011.31056.549113.098226.195339.292452.389565.4871130.97
DN25017.67188.357176.715353.429530.144706.858833.5731767.15
DN30025.447127.235254.469508.938763.4071017.881272.352544.68
DN35034.636173.180346.361692.7211039.081385.441731.803463.61
DN40045.239226.195452.389904.7791357.171809.562261.954523.89
DN45057.256286.278572.5551145.111717.672290.222862.785725.55
DN50070.686353.429706.8581413.722120.582827.433534.297068.58
DN600101.788508.9381017.882035.753053.634071.505089.3810178.8
DN700138.544692.7211385.442770.884156.335541.776927.2113854.4
DN800180.956904.7791809.563619.115428.677238.239047.8018095.6
DN900229.0221145.112290.224580.446870.669047.7911451.122902.2
DN1000282.7431413.722827.435654.878482.3011309.714137.228274.3
DN1200407.1502035.754071.508143.0112214.516286.020357.540715.0
DN1400554.1772770.885541.7711083.516625.322167.127708.855417.7
DN1600723.8233619.117238.2314476.521714.728952.936191.172382.3
DN1800916.0884580.449160.8818321.827482.736643.545804.491608.8
DN20001131.975654.8711309.722619.533929.245238.956548.7113097
DN22001368.486842.3913684.827369.641054.354739.168423.9136848
DN24001628.608143.0116286.032572.048858.165144.181430.1162860
DN26001911.359556.7219113.438226.957340.376453.795567.2191134
DN28002216.7111083.522167.144334.266501.288668.3110835220671
DN30002544.7012723.525446.950893.876340.7101787127235254469